The PM01 Patient Monitor is a state-of-the-art device designed for accurate and reliable monitoring of vital signs in hospital settings. Crafted with durable plastic and metal materials, this portable monitor ensures easy transportation without compromising on stability or quality. Operating at a frequency of 50 Hertz and powered by electricity, it delivers exceptional performance and precise readings with 100% accuracy, supporting critical healthcare decisions. The monitor boasts high-quality attributes, ensuring long-term reliability and effectiveness. Perfect for healthcare professionals, the PM01 Patient Monitor is ideal for hospitals where accuracy and efficiency are paramount. Its new condition and warranty coverage further guarantee peace of mind for buyers while reinforcing trust in its functionality.
ECG Specification
Lead Configuration
- Standard 3 - Lead or 5 - Lead
- 3-Lead RA LA, LL, Lead Method : |, Il
- 5-Lead RA, LAL. RL, V,
- Lead Method : 1 Il, aVR, aVL, aVF, V
Increase
HR
Range
- Adult 15 - 300bpm (beat / minute)
- Neonatal baby children 15 - 350 bpm (beat / minute)
- Precision 1% or #1bpm, the larger prevails
- Resolution 1 bpm (beat / minute)
Sensitivity
- > 200 uV (Peak(o-peak value)
Input Impedance
Bandwidth
- Diagnostic mode 0.05 - 130Hz
- Monitoring Mode 0.5- 40Hz
- Operation mode 1-20Hz
- Operation mode 1-20Hz
- Diagnostic mode > 90 dB
- Monitoring Mode > 100 dB
- Operation mode > 100 dB
Pole Polarization Voltage Range
Pacing Pulse Test
- Test pacing pulse in accordance with the following conditions:
- Amplitude: 2mV - 700mV
- Width: 0.1ms -2ms
- Risetime: 10us - 100us
Pacing pulse inhibition
- When pacing analysis switch is on, pacing pulse in accordance with the following conditions are restrained, but affection against HR calculation.
- Amplitude: 2mV 700mV
- Width 0.1ms - 2ms
- Risetime 10us - 100us
Baseline Recovering Time
- After defibrillation < 3 seconds
Signal Range
- 8 mV (Peak - to - peak value)
Calibrating Signal
- 1mV (Peak-to-peak value), precision 5%
ST Segment Measuring Volume
- Measuring range : -2.0mV - +2,0mV
- Measuring precision : Ranging -0.8 mV - +0.8mV, measuring error is 0.02mV or 10%. The larger prevails. No definition for other ranges.
RESP Specification
- Measuring Method
- RA-LL impedance
RESP Impedance Measuring Range
Base Impedance Range
Bandwidth
RESP Rate
- Range
- Adult: 0-120 BrPM
- Children and neonatal baby: 0-150 BrPM
- Resolution: 1 BrPM
- Precision: 2 BrPM
Asphyxia Alarm
NIBP Specification
Measuring Method
Work Mode
Measuring Interval of Automatic Measuring Mode
- 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240, 480 minute(s)
1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240, 480 minute(s)
PR range
Measuring Range and Precision
Adult:
- Systolic blood pressure 40-270mmHg
- Diastolic blood pressure 10-215mmHg
- Mean blood pressure 20-235mmHg
Children:
- Systolic blood pressure 40-200mmHg
- Diastolic blood pressure 10-150mmHg
- Mean blood pressure 20-165mmHg
Neonatal baby:
- Systolic blood pressure 40-135mmHg
- Diastolic blood pressure 10-100mmHg
- Mean blood pressure 20-110mmHg
- Static pressure range 0-300mmHg
- Static pressure precision 3mmHg
Pressure Precision:
- Max. average error: 5mmHg;
- Max. Standard deviation: 8mmHg
Overvoltage Protection
- Adult mode 300 mmHg
- Children mode 240 mmHg
- Neonatal baby mode 150 mmHg
SpO2 Specification
- SpO2
- 0.3-3
- Range: 0-100%
- Resolution: 1%
- Precision: 70-100% 2 DIGIT
- 0%-69% no definition given
PR
- Range: 20-300bpm
- Resolution: 1bpm
- Precision: 3bpm
TEMP Specification
Suitable for Temperature Sensor
Channel Quantity
Measuring
- Range: 0-50C
- Resolution: 0.1C
- Precision: 0.1C (excluding sensor error)
IBP
- Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range
- ART: 0-300 mmHg
- PA: -6-120 mmHg
- CVP/RAP/LAP/ICP: -10-40 mmHg
- P1/P2: -10-300 mmHg
Press Sensor
- Sensitivity: 5 uV/V/mmHg
- Impedance: 300-3000
- Resolution: 1 mmHg
- Accuracy: 2% or 1mmHg, whichever is greater
- Actualization interval: about 1 Sec