Ventox PM01
Ventox PM01

Ventox PM01

Price 22000.0 INR/ Unit

MOQ : 1 Unit

Ventox PM01 Specification

  • Use
  • Hospital
  • Warranty
  • Yes
  • Power
  • 220 Volt (v)
  • Application
  • To check the vital parameters of the patient
  • Wall Mounted
  • yes
  • Portable
  • Yes
  • Display Type
  • TFT LCD
  • Properties
  • 5 para monitor
  • Accuracy
  • 100 %
  • Material
  • Plastic, Metal
  • Attributes
  • High Quality
  • Condition
  • New
  • Product Type
  • Multipara patient monitor
  • Frequency
  • 50 Hertz (HZ)
  • Display
  • 12.1"
  • Power Source
  • Electric
 

Ventox PM01 Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 10 Units Per Month
  • Delivery Time
  • 1 Days
  • Main Domestic Market
  • All India
 

About Ventox PM01



The PM01 Patient Monitor is a state-of-the-art device designed for accurate and reliable monitoring of vital signs in hospital settings. Crafted with durable plastic and metal materials, this portable monitor ensures easy transportation without compromising on stability or quality. Operating at a frequency of 50 Hertz and powered by electricity, it delivers exceptional performance and precise readings with 100% accuracy, supporting critical healthcare decisions. The monitor boasts high-quality attributes, ensuring long-term reliability and effectiveness. Perfect for healthcare professionals, the PM01 Patient Monitor is ideal for hospitals where accuracy and efficiency are paramount. Its new condition and warranty coverage further guarantee peace of mind for buyers while reinforcing trust in its functionality.

Features

  • 12.1 inch High resolution Color TFT LCD display.
  • Real time S-T segment analysis, pace-maker detection.
  • Indication of Incorrect manipulation and malfunction analysis.
  • Patient info input management function.
  • Multi-lead ECG waveforms display in phase.
  • Large volume of tabular and graphic trends information storage and easy to recall.
  • Capture dynamic waveforms.
  • Efficient resistance to interference of defibrillator and HF knife.
  • UP to 2 hours working capacity of built-in rechargeable battery.
  • Unique accessory management cabinet.
  • Networking capacity.
  • Optional: IBP, ETCO2 and 2-1BP
  • STANDARD: ECG, NIBP, SpO2, RESP, TEMP, PR/HR

TECHNICAL SPECIFICATIONS

ECG Specification

Lead Configuration

  • Standard 3 - Lead or 5 - Lead
  • 3-Lead RA LA, LL, Lead Method : |, Il
  • 5-Lead RA, LAL. RL, V,
  • Lead Method : 1 Il, aVR, aVL, aVF, V

Increase

  • 250, 500, 1000, 2000

HR

Range

  • Adult 15 - 300bpm (beat / minute)
  • Neonatal baby children 15 - 350 bpm (beat / minute)
  • Precision 1% or #1bpm, the larger prevails
  • Resolution 1 bpm (beat / minute)

Sensitivity

  • > 200 uV (Peak(o-peak value)

Input Impedance

  • > 5 (megohm)

Bandwidth

  • Diagnostic mode 0.05 - 130Hz
  • Monitoring Mode 0.5- 40Hz
  • Operation mode 1-20Hz
  • Operation mode 1-20Hz
  • Diagnostic mode > 90 dB
  • Monitoring Mode > 100 dB
  • Operation mode > 100 dB

Pole Polarization Voltage Range

  • 300mV

Pacing Pulse Test

  • Test pacing pulse in accordance with the following conditions:
  • Amplitude: 2mV - 700mV
  • Width: 0.1ms -2ms
  • Risetime: 10us - 100us

Pacing pulse inhibition

  • When pacing analysis switch is on, pacing pulse in accordance with the following conditions are restrained, but affection against HR calculation.
  • Amplitude: 2mV 700mV
  • Width 0.1ms - 2ms
  • Risetime 10us - 100us

Baseline Recovering Time

  • After defibrillation < 3 seconds

Signal Range

  • 8 mV (Peak - to - peak value)

Calibrating Signal

  • 1mV (Peak-to-peak value), precision 5%

ST Segment Measuring Volume

  • Measuring range : -2.0mV - +2,0mV
  • Measuring precision : Ranging -0.8 mV - +0.8mV, measuring error is 0.02mV or 10%. The larger prevails. No definition for other ranges.

RESP Specification

  • Measuring Method
  • RA-LL impedance

RESP Impedance Measuring Range

  • 0.3-3

Base Impedance Range

  • 200-4000

Bandwidth

  • 0.1-2.5Hz

RESP Rate

  • Range
  • Adult: 0-120 BrPM
  • Children and neonatal baby: 0-150 BrPM
  • Resolution: 1 BrPM
  • Precision: 2 BrPM

Asphyxia Alarm

  • 10-40 seconds

NIBP Specification

Measuring Method

  • Pulse wave oscillometry

Work Mode

  • Manual/Automatic / STAT

Measuring Interval of Automatic Measuring Mode

  • 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240, 480 minute(s)

1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240, 480 minute(s)

  • 5 minutes

PR range

  • 40-240 bpm

Measuring Range and Precision

  • Range

Adult:

  • Systolic blood pressure 40-270mmHg
  • Diastolic blood pressure 10-215mmHg
  • Mean blood pressure 20-235mmHg

Children:

  • Systolic blood pressure 40-200mmHg
  • Diastolic blood pressure 10-150mmHg
  • Mean blood pressure 20-165mmHg

Neonatal baby:

  • Systolic blood pressure 40-135mmHg
  • Diastolic blood pressure 10-100mmHg
  • Mean blood pressure 20-110mmHg
  • Static pressure range 0-300mmHg
  • Static pressure precision 3mmHg

Pressure Precision:

  • Max. average error: 5mmHg;
  • Max. Standard deviation: 8mmHg

Overvoltage Protection

  • Adult mode 300 mmHg
  • Children mode 240 mmHg
  • Neonatal baby mode 150 mmHg

SpO2 Specification

  • SpO2
  • 0.3-3
  • Range: 0-100%
  • Resolution: 1%
  • Precision: 70-100% 2 DIGIT
  • 0%-69% no definition given

PR

  • Range: 20-300bpm
  • Resolution: 1bpm
  • Precision: 3bpm

TEMP Specification

Suitable for Temperature Sensor

  • YSI series, CYF series

Channel Quantity

  • Channel Quantity

Measuring

  • Range: 0-50C
  • Resolution: 0.1C
  • Precision: 0.1C (excluding sensor error)

IBP

  • Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2

Measuring and alarm range

  • ART: 0-300 mmHg
  • PA: -6-120 mmHg
  • CVP/RAP/LAP/ICP: -10-40 mmHg
  • P1/P2: -10-300 mmHg

Press Sensor

  • Sensitivity: 5 uV/V/mmHg
  • Impedance: 300-3000
  • Resolution: 1 mmHg
  • Accuracy: 2% or 1mmHg, whichever is greater
  • Actualization interval: about 1 Sec

FAQs of PM01 Patient Monitor:


Q: What makes the PM01 Patient Monitor portable?

A: The lightweight design, combined with sturdy material construction, makes it easy to transport within the hospital setting.

Q: Is the monitor powered electrically?

A: Yes, the PM01 Patient Monitor uses an electric power source for operation.

Q: How accurate is the device?

A: The PM01 Patient Monitor provides 100% accuracy in its readings, ensuring reliable and precise results.

Q: Is there a warranty included with the PM01 Patient Monitor?

A: Yes, the product comes with a warranty to ensure user satisfaction and support.

Q: Can this monitor be used in settings other than a hospital?

A: The PM01 Patient Monitor is specifically designed to meet hospital requirements, making it ideal for such environments.